AGC sunsep™ membrane dryers & humidifiers · North American supply and engineering support
Membrane gas drying, sized for your instrument.
Brink Innovation supplies and integrates AGC sunsep™ fluoropolymer hollow-fiber dryers and dehumidification tubes for analyzers, OEM instruments, CEMS and air monitoring. Send us your current part number or your operating conditions and we'll recommend a configuration to evaluate.
Replacing an existing dryer?
Common starting points. Final selection depends on your conditions.
No power required
Driven by the water-vapor partial-pressure difference. No heaters, chillers or desiccant.
Selective for water vapor
Non-porous fluoropolymer membrane with very low permeability to most other gases.
Custom lengths & fittings
Standard SKUs, plus configured lengths, end fittings and small assemblies.
Engineering replies, fast
We reply to sizing and quote requests within one business day.
Product families
Standard parts can be ordered online. Configured, OEM and volume parts are quoted. All specifications are condition-dependent; we'll confirm sizing for your flow, pressure, temperature and dew-point target.
SWG-A01 SERIES
Single-tube analytical sample dryers
For GC, analyzers and CEMS sample lines. Up to 4 L/min. 12 to 144 in. Polypropylene or PVDF fittings, ¼ in (6.35 mm) ports.
From $260
SWG-035 / SWG-100
Multi-tube analytical dryers
Higher-flow sample conditioning in a multi-fiber module. SWG-035: up to about 20 L/min, 24 and 48 in. SWG-100: up to about 30 L/min, 12, 24 and 48 in, polypropylene or SUS316. ¼ in supply and ⅛ in purge ports (NPT or Rc).
Quoted to your conditions
SWT-1.3 / SWT-3.0
Aquadrive braided micro-flow tubes
Humidity conditioning for sensors and embedded OEM modules. SWT-1.3: about 300 mL/min. SWT-3.0: about 2 L/min. Barb, Luer, straight 4 mm or 6 mm tube, or stainless-tube ends. MOQ 10 (SWT-1.3) or 5 (SWT-3.0).
Quoted · OEM volume pricing
SWB SERIES
Point-of-use compressed-air dryers
Compact inline drying of instrument air and non-corrosive gases. A 5 µm filter and drain upstream are recommended. Custom and OEM modules available.
Quoted to your conditions
Need a length or fitting not shown? Ask for a configured part.
Will it fit your conditions?
| Family | Max recommended flow | Supply pressure | Temperature and notes |
|---|---|---|---|
| SWG-A01Analytical, single tube | 4 L/min | -6 to 72 psig at 25 °CLower when hot | -15 to 80 °C (PP fittings), to 100 °C (PVDF) |
| SWG-035 / SWG-100Analytical, multi-tube | About 20 / 30 L/min | -6 to 72 psig at 25 °CLower above 45 °C | -15 to 60 °C |
| SWT-1.3 / SWT-3.0Micro-flow tubes | 300 mL/min / 2 L/min | Depends on conditions | AGC does not publish limits for these tubes. Send your conditions and we'll confirm with the manufacturer before you buy samples. |
| SWB / SWC / SWFCompressed air | 15 to 1,800 L/min by model | 0 to 120 psig | -20 to 55 °C. 5 µm filter and drain upstream. |
Published figures from the AGC sunsep™ catalog (2025); maximum flows are the top of AGC's performance curves. Purge gas up to about 7 psig. Keep inlet and ambient temperatures within 5 °C, with no freezing or liquid water at the inlet. Outside these ranges? Tell us anyway. If sunsep™ won't work, we'll say so.
How a membrane dryer works
Wet sample gas flows through the inside of a hollow-fiber membrane. Water vapor moves through the membrane wall toward the drier purge gas on the outside, which carries it away. Most other gas components stay in the sample.
Reverse which side is drier and the same part humidifies a gas stream instead.
Performance depends on flow, pressure, temperature and purge. Purge depends on the family: AGC's analytical (SWG) performance curves use a purge flow of twice the sample flow; compressed-air (SWB) dryers typically use 10 to 20% of supply flow. Keep supply and purge temperatures close and avoid liquid condensate at the inlet.
Where sunsep™ is used
Analyzers & gas chromatography
Remove water vapor ahead of GC, FTIR, TDLAS and electrochemical measurements to reduce drift, condensation and reruns.
CEMS & process monitoring
Stabilize moisture load in the conditioning train before the analyzer. Sized for your flow, pressure and target dew point.
Ambient air monitoring
Smooth out humidity swings in station and network instruments with a simple inline part.
OEM & embedded modules
Micro-flow humidity conditioning for sensors and instrument builds, with custom lengths and fittings. A second source for an existing membrane part.
Medical or veterinary device?
We can work with medical, veterinary and life-science device makers, and the process is different. These dryers are industrial components that have not been evaluated for medical use. Evaluation samples are for non-clinical evaluation only and may not be used in clinical trials. Production use requires a medical-use agreement with the manufacturer, and the device maker takes responsibility for qualification, risk and regulatory approval. Tell us early and we'll walk you through it. How this works
Working with Brink
01
Share your conditions
Flow, pressure, temperature, dew-point target, fittings, or simply your current part number.
02
Get a recommendation
A configuration to evaluate, with pricing. If sunsep™ isn't a fit for your conditions, we'll say so.
03
Evaluate samples
Order evaluation quantities and test in your instrument. We help interpret results.
04
Move to production
Volume pricing and a supply plan for your build rate. Typical lead time is 3 to 5 weeks from order: closer to 3 for standard parts the manufacturer has in stock in small quantities, closer to 5 for items not in stock. All parts are manufactured by AGC in Japan. We confirm lead time when we quote.
Common questions
How do I size a sunsep™ dryer?
Send flow (L/min), pressure (psig), inlet temperature, target atmospheric dew point and fitting preferences. We'll recommend the series and length.
What purge ratio should I plan for?
It depends on the application. For analytical SWG dryers, AGC's published curves use purge at twice the sample flow. Compressed-air SWB dryers typically use 10 to 20% of supply flow. We'll confirm the setting for your target.
How about pressure drop?
It rises with flow and length. Choose the shortest length that meets your dew-point target and keep fittings sized appropriately.
Can you replace my Nafion™-based part?
Send the model and your conditions. We'll propose the closest sunsep™ configuration to evaluate. See the cross-reference.
How can I lower the outlet dew point?
Lower the inlet temperature, raise supply pressure, reduce supply or product flow, or increase purge flow where applicable.
Request a quote or sizing
Tell us about the application. A current part number is often enough to start. The more detail you send, the more specific our recommendation will be.
Or email us at applications@brinkinnovation.com. We reply within one business day.