Cross-reference · PD series
Alternative to Perma Pure PD-series dryers: sunsep™ SWG-035 and SWG-100
For multi-tube sample dryers in CEMS and process monitoring, the sunsep™ SWG-035 and SWG-100 are the nearest formats, with ¼ NPT supply and ⅛ NPT purge ports, in polypropylene or SUS316.
Part-number cross-reference
| If you use | Perma Pure recommended flow | sunsep™ starting point | Notes |
|---|---|---|---|
| PD-50T-24 / -48 | 2 to 10 L/min | SWG-035-06/PP / -12/PP | 24 and 48 in. Up to about 20 L/min on AGC's curves. |
| PD-100T-12 / -24 / -48 | 4 to 20 L/min | SWG-100-03 / -06 / -12 | 12, 24 and 48 in. Up to about 30 L/min on AGC's curves. PP or SUS316. |
| PD-200T | 10 to 40 L/min | SWG-100 (to about 30 L/min) | Above 30 L/min, ask us. |
| 12 in PD-50T, or 72 in any series | Ask us | No standard SWG-035 at 12 in or any SWG at 72 in. |
Published limits, side by side
| Published figure | sunsep™ | Perma Pure | Note |
|---|---|---|---|
| Max recommended flow | SWG-035: about 20 L/min. SWG-100: about 30 L/min | Up to 40 L/min (PD-200T) | |
| Max temperature | 60 °C | 120 °C | Check hot samples. |
| Max pressure | 72 psig at 25 °C, lower when hot | 80 psig | |
| Purge | Published curves at 2× sample flow, -40 °C dew-point purge | 2 to 3× sample flow, -40 °C dew-point purge |
Matches are by format, size and connection, not a claim of identical performance. Figures are as published by each manufacturer under its own test conditions (sunsep™: AGC catalog 2025; Perma Pure: product pages and datasheets on salaera.com, Nov 2026) and may change. Confirm in your application before switching. Perma Pure® is a trademark of its owner and Nafion™ of The Chemours Company; names are used for identification only. Brink Innovation is not affiliated with either.
Before you switch
Conditions
Flow, pressure and temperature against the figures above. Keep inlet and ambient temperatures close and avoid liquid at the inlet.
Fit
Length, end fittings and bend radius in your enclosure. We can quote custom lengths and ends.
Evaluate side by side
Order a small quantity and test it in your instrument before changing your bill of materials. We help read the results.
Send us your part number
Tell us the part you use now and your flow, pressure and temperature. We reply within one business day with a configuration to evaluate and a price.